{"id":170,"date":"2020-06-12T23:41:12","date_gmt":"2020-06-13T02:41:12","guid":{"rendered":"http:\/\/crc.viskoo.com.br\/?p=170"},"modified":"2026-05-20T08:45:40","modified_gmt":"2026-05-20T11:45:40","slug":"fleximetria-otica","status":"publish","type":"post","link":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/","title":{"rendered":"Optical fleximetry"},"content":{"rendered":"\n<p>Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens system with a resolution of 0.2 \u00b5m on specimens measuring 85 x 5 x 5 mm<sup>3<\/sup>. The analyses can be conducted to obtain high-precision results in hot flexural strength tests, evaluations of pyroplastic deformation with the corresponding pyroplasticity index (PI) calculations, hydro-deformation tests (curvatures caused by applying water to the surface of unfired ceramic tiles), and analyses of coupling stress between layers with different thermal expansion coefficients.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens system with a resolution of 0.2 \u00b5m on specimens measuring 85 x 5 x 5 mm3. The analyses can be conducted to obtain high-precision results in hot flexural strength tests, evaluations [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":132,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[22,447],"tags":[137,220,219,221,217,218,223,226,227,222,228,225,224],"class_list":["post-170","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-analises","category-fisico-quimicas","tag-deformacao","tag-deformacao-a-quente","tag-deformacao-piroplastica","tag-flexao-a-quente","tag-fleximetria-otica","tag-fleximetro-otico","tag-hidrodeformacao","tag-indice-de-piroplasticidade","tag-ip","tag-misura","tag-piroplastia","tag-plataforma-otica","tag-tensao-de-acoplamento"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Optical fleximetry &#8226; CRC<\/title>\n<meta name=\"description\" content=\"Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/crceram.com.br\/en\/fleximetria-otica\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Optical fleximetry &#8226; CRC\" \/>\n<meta property=\"og:description\" content=\"Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/crceram.com.br\/en\/fleximetria-otica\/\" \/>\n<meta property=\"og:site_name\" content=\"CRC\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-13T02:41:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-20T11:45:40+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/crceram.com.br\/en\/wp-content\/uploads\/2020\/06\/imagem-post-sem-foto.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"otavio.q@viskoo.com.br\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"otavio.q@viskoo.com.br\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/\"},\"author\":{\"name\":\"otavio.q@viskoo.com.br\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/#\\\/schema\\\/person\\\/2a3754e89602d540fe33b6ba05067937\"},\"headline\":\"Optical fleximetry\",\"datePublished\":\"2020-06-13T02:41:12+00:00\",\"dateModified\":\"2026-05-20T11:45:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/\"},\"wordCount\":89,\"image\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/imagem-post-sem-foto.png\",\"keywords\":[\"deforma\u00e7\u00e3o\",\"deforma\u00e7\u00e3o a quente\",\"deforma\u00e7\u00e3o piropl\u00e1stica\",\"flex\u00e3o a quente\",\"fleximetria \u00f3tica\",\"flex\u00edmetro \u00f3tico\",\"hidrodeforma\u00e7\u00e3o\",\"\u00edndice de piroplasticidade\",\"IP\",\"Misura\",\"piroplastia\",\"plataforma \u00f3tica\",\"tens\u00e3o de acoplamento\"],\"articleSection\":[\"Analyses\",\"Physicochemical\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/\",\"url\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/\",\"name\":\"Optical fleximetry &#8226; CRC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/imagem-post-sem-foto.png\",\"datePublished\":\"2020-06-13T02:41:12+00:00\",\"dateModified\":\"2026-05-20T11:45:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/#\\\/schema\\\/person\\\/2a3754e89602d540fe33b6ba05067937\"},\"description\":\"Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#primaryimage\",\"url\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/imagem-post-sem-foto.png\",\"contentUrl\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/imagem-post-sem-foto.png\",\"width\":1920,\"height\":1080,\"caption\":\"imagem-CRC\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/fleximetria-otica\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"In\u00edcio\",\"item\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Optical fleximetry\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/\",\"name\":\"CRC\",\"description\":\"Ceramic Coatings Center\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/crceram.com.br\\\/en\\\/#\\\/schema\\\/person\\\/2a3754e89602d540fe33b6ba05067937\",\"name\":\"otavio.q@viskoo.com.br\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Optical fleximetry &#8226; CRC","description":"Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/","og_locale":"en_US","og_type":"article","og_title":"Optical fleximetry &#8226; CRC","og_description":"Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens.","og_url":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/","og_site_name":"CRC","article_published_time":"2020-06-13T02:41:12+00:00","article_modified_time":"2026-05-20T11:45:40+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/crceram.com.br\/en\/wp-content\/uploads\/2020\/06\/imagem-post-sem-foto.png","type":"image\/png"}],"author":"otavio.q@viskoo.com.br","twitter_card":"summary_large_image","twitter_misc":{"Written by":"otavio.q@viskoo.com.br"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#article","isPartOf":{"@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/"},"author":{"name":"otavio.q@viskoo.com.br","@id":"https:\/\/crceram.com.br\/en\/#\/schema\/person\/2a3754e89602d540fe33b6ba05067937"},"headline":"Optical fleximetry","datePublished":"2020-06-13T02:41:12+00:00","dateModified":"2026-05-20T11:45:40+00:00","mainEntityOfPage":{"@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/"},"wordCount":89,"image":{"@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#primaryimage"},"thumbnailUrl":"https:\/\/crceram.com.br\/en\/wp-content\/uploads\/2020\/06\/imagem-post-sem-foto.png","keywords":["deforma\u00e7\u00e3o","deforma\u00e7\u00e3o a quente","deforma\u00e7\u00e3o piropl\u00e1stica","flex\u00e3o a quente","fleximetria \u00f3tica","flex\u00edmetro \u00f3tico","hidrodeforma\u00e7\u00e3o","\u00edndice de piroplasticidade","IP","Misura","piroplastia","plataforma \u00f3tica","tens\u00e3o de acoplamento"],"articleSection":["Analyses","Physicochemical"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/","url":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/","name":"Optical fleximetry &#8226; CRC","isPartOf":{"@id":"https:\/\/crceram.com.br\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#primaryimage"},"image":{"@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#primaryimage"},"thumbnailUrl":"https:\/\/crceram.com.br\/en\/wp-content\/uploads\/2020\/06\/imagem-post-sem-foto.png","datePublished":"2020-06-13T02:41:12+00:00","dateModified":"2026-05-20T11:45:40+00:00","author":{"@id":"https:\/\/crceram.com.br\/en\/#\/schema\/person\/2a3754e89602d540fe33b6ba05067937"},"description":"Assessment of deformations that occur during heat treatment at high temperatures of materials subjected to bending stress. Monitoring is carried out by a lens.","breadcrumb":{"@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/crceram.com.br\/en\/fleximetria-otica\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#primaryimage","url":"https:\/\/crceram.com.br\/en\/wp-content\/uploads\/2020\/06\/imagem-post-sem-foto.png","contentUrl":"https:\/\/crceram.com.br\/en\/wp-content\/uploads\/2020\/06\/imagem-post-sem-foto.png","width":1920,"height":1080,"caption":"imagem-CRC"},{"@type":"BreadcrumbList","@id":"https:\/\/crceram.com.br\/en\/fleximetria-otica\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"In\u00edcio","item":"https:\/\/crceram.com.br\/en\/"},{"@type":"ListItem","position":2,"name":"Optical fleximetry"}]},{"@type":"WebSite","@id":"https:\/\/crceram.com.br\/en\/#website","url":"https:\/\/crceram.com.br\/en\/","name":"CRC","description":"Ceramic Coatings Center","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/crceram.com.br\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/crceram.com.br\/en\/#\/schema\/person\/2a3754e89602d540fe33b6ba05067937","name":"otavio.q@viskoo.com.br"}]}},"_links":{"self":[{"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/posts\/170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/comments?post=170"}],"version-history":[{"count":3,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/posts\/170\/revisions"}],"predecessor-version":[{"id":1354,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/posts\/170\/revisions\/1354"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/media\/132"}],"wp:attachment":[{"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/media?parent=170"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/categories?post=170"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/crceram.com.br\/en\/wp-json\/wp\/v2\/tags?post=170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}